Wabash Storage Lakeland, FL
New Construction
Arch Plans
(click to expand/collapse)
Civil Plans
(click to expand/collapse)
Name | Size | ||
C100-COVER-SHEET-Rev.0 | 784.0 KB | ||
C101-GENERAL-NOTES-Rev.0 | 1.1 MB | ||
C105-DEMOLITION-&-EXISTING-CONDITIONS-PLAN-Rev.0 | 951.5 KB | ||
C150-AERIAL-SITE-PLAN-Rev.0 | 2.0 MB | ||
C200-SITE-PLAN-Rev.0 | 822.0 KB | ||
C300-GRADING-&-DRAINAGE-PLAN-Rev.0 | 934.0 KB | ||
C350-POND-GEOMETRY-AND-DETAILS-Rev.0 | 695.1 KB | ||
C400-UTILITY-PLAN-Rev.0 | 655.8 KB | ||
C401-UTILITY-DETAILS-Rev.0 | 5.4 MB | ||
C402-UTILITY-DETAILS-Rev.0 | 2.9 MB | ||
C500-CONSTRUCTION-DETAILS-Rev.0 | 705.0 KB |
Electrical Plans
(click to expand/collapse)
Name | Size | ||
E0.1-ELECTRICAL-COVER-SHEET-Rev.1 | 398.2 KB | ||
E1.0-OVERALL-FLOOR-PLAN-Rev.0 | 541.5 KB | ||
E1.1-ENLARGED-POWER-PLAN-'A'-Rev.1 | 757.6 KB | ||
E1.2-ENLARGED-POWER-PLAN-'B'-Rev.1 | 751.5 KB | ||
E1.3-ENLARGED-ROOF-POWER-PLAN-'A'-Rev.0 | 666.1 KB | ||
E1.4-ENLARGED-ROOF-POWER-PLAN-'B'-Rev.0 | 671.3 KB | ||
E2.1-ENLARGED-LIGHTING-PLAN-'A'-Rev.1 | 751.7 KB | ||
E2.2-ENLARGED-LIGHTING-PLAN-'B'-Rev.1 | 724.0 KB | ||
E5.1-POWER-RISER-DIAGRAM-AND-PANELBOARDS-Rev.1 | 297.8 KB | ||
E6.1-FIRE-ALARM-SYSTEM-RISER-DIAGRAM-Rev.0 | 304.0 KB | ||
E7.1-ELECTRICAL-DETAILS-Rev.0 | 288.6 KB | ||
E8.1-ELECTRICAL-SPECIFICATIONS-Rev.0 | 270.7 KB |
Fire Protection Plans
(click to expand/collapse)
Name | Size | ||
F0.1-FIRE-PROTECTION-COVER-SHEET-Rev.1 | 223.7 KB | ||
F1.0-OVERALL-FIRE-PROTECTION-PLAN-Rev.1 | 892.1 KB | ||
F1.1-ENLARGED-FIRE-PROTECTION-PLAN-'A'-Rev.1 | 1.0 MB | ||
F1.2-ENLARGED-FIRE-PROTECTION-PLAN-'B'-Rev.1 | 1.0 MB | ||
F7.1-FIRE-PROTECTION-DETAILS-Rev.1 | 245.3 KB | ||
F7.2-FIRE-PROTECTION-DETAILS-Rev.1 | 234.5 KB | ||
F8.1-FIRE-PROTECTION-SCHEDULES-AND-SPECIFICATIONS-Rev.0 | 130.8 KB |
Landscape & Irrigation Plans
(click to expand/collapse)
Name | Size | ||
IR100-IRRIGATION-PLAN-Rev.0 | 2.7 MB | ||
IR101-IRRIGATION-NOTES-Rev.0 | 2.2 MB | ||
IR102-IRRIGATION-DETAILS-Rev.0 | 2.5 MB | ||
L100-CODE-REQUIRED-LANDSCAPE-PLAN-Rev.0 | 2.6 MB | ||
L101-LANDSCAPE-NOTES-Rev.0 | 2.2 MB | ||
L102-LANDSCAPE-DETAILS-Rev.0 | 2.8 MB |
Mechanical Plans
(click to expand/collapse)
Name | Size | ||
M0.1-MECHANICAL-COVER-SHEET-Rev.1 | 212.7 KB | ||
M1.0-OVERALL-FLOOR-PLAN-Rev.1 | 401.3 KB | ||
M1.1-ENLARGED-MECHANICAL-PLAN-'A'-Rev.1 | 603.1 KB | ||
M1.2-ENLARGED-MECHANICAL-PLAN-'B'-Rev.1 | 633.1 KB | ||
M1.3-ENLARGED-ROOF-PLAN-'A'-Rev.1 | 682.2 KB | ||
M1.4-ENLARGED-ROOF-PLAN-'B'-Rev.1 | 660.1 KB | ||
M7.1-MECHANICAL-DETAILS-Rev.1 | 204.3 KB | ||
M8.1-MECHANICAL-SCHEDULES-Rev.1 | 199.8 KB | ||
M9.1-MECHANICAL-SPECIFICATIONS-Rev.1 | 212.9 KB | ||
M9.2-MECHANICAL-SPECIFICATIONS-Rev.1 | 199.6 KB |
PEMB Plans
(click to expand/collapse)
Name | Size | ||
D1-DETAILS-Rev.0 | 659.9 KB | ||
D2-DETAILS-Rev.0 | 799.4 KB | ||
KS1-COVER-PAGE,-&-GENERAL-NOTES-Rev.0 | 852.0 KB | ||
KS2-BUILDING-A-ROOF-FRAMING-PLAN-SEG.-#1-Rev.0 | 872.7 KB | ||
KS3-BUILDING-A-ROOF-FRAMING-PLAN-SEG.-#2-Rev.0 | 846.1 KB | ||
KS4-BUILDING-A-PARTITION-PLAN-SEG.-#1-Rev.0 | 914.7 KB | ||
KS5-BUILDING-A-PARTITION-PLAN-SEG.-#2-Rev.0 | 902.9 KB | ||
KS6-BUILDING-A-SHEARWALL-LAYOUT-SEG.-#1-Rev.0 | 760.6 KB | ||
KS7-BUILDING-A-SHEARWALL-LAYOUT-SEG.-#2-Rev.0 | 755.7 KB | ||
KS8-BUILDING-A-HEAVY-STEEL-LAYOUT-SEG.-#1-Rev.0 | 721.1 KB | ||
KS9-BUILDING-A-CROSS-SECTION-Rev.0 | 844.0 KB |
Plumbing Plans
(click to expand/collapse)
Name | Size | ||
P0.1-PLUMBING-COVER-SHEET-Rev.1 | 219.9 KB | ||
P1.0-OVERALL-FLOOR-PLAN-Rev.1 | 706.6 KB | ||
P1.1-ENLARGED-PLUMBING-PLANS-Rev.1 | 341.6 KB | ||
P7.1-PLUMBING-DETAILS-Rev.1 | 243.6 KB | ||
P7.2-PLUMBING-DETAILS-Rev.1 | 238.4 KB | ||
P8.1-PLUMBING-SCHEDULES-Rev.1 | 220.6 KB | ||
P9.1-PLUMBING-SPECIFICATIONS-Rev.1 | 197.3 KB |
Revised Architectural & MEP Plans
(click to expand/collapse)
The plan revisions include, but are not necessarily limited to, the following items:
• Revisions to MEP plans include:
• Reduced the number of AHU’s in the storage area to 8.
• Removed some ductwork from the AHU’s
• Relocated the condensers on the roof to be located directly above each AHU.
• Revised lighting layout – reduced interior lighting
• Removed outlets in storage with the exception of those required for servicing air handlers
• Revisions to Arch plans include:
• Removed EIFS from north elevation and relocate the exterior electrical room door inside
• Changed the roofing to standing seam
• Shortened the canopies over the entry doors and removed north and south canopies
• Revised the unit mix and lighting
• Removed loading zone
• Revisions to MEP plans include:
• Reduced the number of AHU’s in the storage area to 8.
• Removed some ductwork from the AHU’s
• Relocated the condensers on the roof to be located directly above each AHU.
• Revised lighting layout – reduced interior lighting
• Removed outlets in storage with the exception of those required for servicing air handlers
• Revisions to Arch plans include:
• Removed EIFS from north elevation and relocate the exterior electrical room door inside
• Changed the roofing to standing seam
• Shortened the canopies over the entry doors and removed north and south canopies
• Revised the unit mix and lighting
• Removed loading zone
Structural Plans
(click to expand/collapse)
Name | Size | ||
S001-STRUCTURAL-NOTES-AND-SHEET-INDEX-Rev.0 | 378.3 KB | ||
S002-STRUCTURAL-CRITERIA-AND-TYPICAL-NOTES-Rev.0 | 1.3 MB | ||
S011-CONCRETE-SCHEDULES-AND-DETAILS-Rev.0 | 439.4 KB | ||
S111-FOUNDATION-PLAN-Rev.0 | 568.1 KB | ||
S112-FOUNDATION-PLAN-Rev.0 | 518.3 KB | ||
S113-FOUNDATION-PLAN-Rev.0 | 550.4 KB | ||
S121-ROOF-FRAMING-PLAN-Rev.0 | 409.0 KB | ||
S122-ROOF-FRAMING-PLAN-Rev.0 | 406.3 KB | ||
S123-ROOF-FRAMING-PLAN-Rev.0 | 434.8 KB | ||
S311-STRUCTURAL-SECTIONS-Rev.0 | 537.4 KB |